1800/1800i Curtain Wall

  • Exterior View

  • Interior View

    Features & Information
  • Standard Features
    • Offered with both screw spline and shear block assembly
    • Captured exterior pressure glazing
    • Thermal isolator between exterior and interior aluminum at Series 1800 plus additional thermal struts for enhanced thermal performance at Series 1800i
    • Available in 6”, 7 ½” or 9 ½” depths to accommodate various sizes and loads
    • Dual finish capability
    • AAMA 2603/2604/2605 painted or AAMA 611 anodized finishes
  • Optional Features
    • Exterior applied extruded aluminum or internal roll formed muntin grids
    • Various adaptors and fillers
    • Integral blinds with interior access panel
    • 2-sided horizontal capture
    • Glazing adapters for glazed-in installation of operable windows of varying frame depths
    • Hurricane Windborne Debris Impact Resistance (Large Missile)
  • Performance Charts
  • Downloadable Details, Data Sheet + Specification
We have you covered

Architects must balance longevity, cost, risk and beauty while controlling the effects of temperature, water, wind, acoustics and storm-driven projectiles. Architects collaborate best with manufacturers driven by an equal passion for balance and control.

Performance Data1
Series Operation AMAA
Rating
Test Size
(inches)
Air (cfm/ft2)
@ 6.24 psf
Water
(psf)
Design Pressure
(psf)
Structural Overload
(psf)
OITC U-Factor
(BTU/HR/FT2/F)
1800 Curtain Wall N/A 113 x 192 <0.01 21 60 90 Consult AWM See Below
1800i Curtain Wall N/A 113 x 192 0.01 21 60 90 Consult AWM See Below
  • 1 Based on independent certified laboratory testing per AAMA/WDMA/CSA 101/I.S.2/A440. Field results will vary based on size, test methods, accessories & conditions.
Thermal Performance Chart1
Curtainwall Size (Inches) CENTER OF INSULATED GLASS U-FACTOR/SPACER TYPE (“Alum.” = Aluminum, “Warm” = Warm Edge) 2
0.33/Alum. 0.33/Warm 0.29/Alum. 0.29/Warm 0.24/Alum. 0.24/Warm 0.20/Alum. 0.20/Warm
79 x 79 Series 1800 0.480 0.461 0.451 0.430 0.416 0.394 0.377 0.357
79 x 79 Series 1800i 0.437 0.408 0.407 0.377 0.372 0.340 0.331 0.302
  • 1Based on independent certified simulations in accordance with NFRC 100
  • 2Consult AWM for additional configurations
  • *Designates NFRC Gateway size
Thermal Performance Chart1
Window Size WHOLE WINDOW U-FACTOR USING ARGON FILLED SPUTTER COAT LOW-E #2 INSULATED GLASS WITH A WARM EDGE SPACER2 2
  • 1 Based on independent certified simulations in accordance with NFRC 100
  • 2 Consult AWM for additional configurations
  • * Designates NFRC Gateway size

Typical Details

Select which format you would like to download:

PDF CAD

Coming Soon

This content has not been uploaded yet, but is coming soon. If you have any questions about this product please feel free to contact us.

Contact Us

We can test our windows to AAMA ratings that are amongst the highest in the country. Our total manufacturing control gives you total creative control.

Ken Thompson