3100i Casement

    Features & Information
  • Standard Features
    • Narrow sightlines for historic replication
    • Overlapping vents with concave or beveled glazing leg to simulate original steel windows
    • 35 mm thermal struts provide exceptional U-values and dual finish capability
    • Wet glazed with structural silicone for maximum seal strength and water resistance
    • White bronze cam locks
    • AAMA 2603/2604/2605 painted or AAMA 611 anodized finishes
  • Optional Features
    • Concave or beveled true, applied or between the lites of dual glazing muntin grids
    • Floating vents to match original steel sash (reduces structural rating)
    • Dual glazing with removable access panels (allows for vandal resistant polycarbonate glazing or integral blinds, 5/8" or 1" deep)
    • Insect screens (fiberglass, aluminum or stainless-steel mesh)
    • Hurricane Windborne Debris Impact Resistance (Large Missile)
    • Multi-point locks, custodial hardware, aluminum butt hinges and roto-operators
    • Limit devices (NYCDOH stamped where applicable)
  • Performance Charts
  • Downloadable Details, Data Sheet + Specification
We have you covered

Architects must balance longevity, cost, risk and beauty while controlling the effects of temperature, water, wind, acoustics and storm-driven projectiles. Architects collaborate best with manufacturers driven by an equal passion for balance and control.

Performance Data1
Series Operation AMAA
Rating
Test Size
(inches)
Air (cfm/ft2)
@ 6.24 psf
Water
(psf)
Design Pressure
(psf)
Structural Overload
(psf)
OITC U-Factor
(BTU/HR/FT2/F)
3100i (Steel Replica) Outswing AW-PG150 36 x 60 0.01 25 150 225 Consult AWM See Below
  • 1 Based on independent certified laboratory testing per AMAA/WDMA/CSA/101/I.S.2/A440. Field results will vary based on size, test methods, accessories & conditions.
Thermal Performance Chart1
Window Size (Inches) CENTER OF INSULATED GLASS U-FACTOR/SPACER TYPE (“Alum.” = Aluminum, “Warm” = Warm Edge) 2
0.33/Alum. 0.33/Warm 0.29/Alum. 0.29/Warm 0.24/Alum. 0.24/Warm 0.20/Alum. 0.20/Warm
24 x 59* 0.481 0.465 0.458 0.441 0.430 0.413 0.392 0.377
36 x 60 0.448 0.435 0.421 0.408 0.389 0.376 0.345 0.334
  • 1Based on independent certified simulations in accordance with NFRC 100
  • 2Consult AWM for additional configurations
  • *Designates NFRC Gateway size
Thermal Performance Chart1
Window Size WHOLE WINDOW U-FACTOR USING ARGON FILLED SPUTTER COAT LOW-E #2 INSULATED GLASS WITH A WARM EDGE SPACER2 2
  • 1 Based on independent certified simulations in accordance with NFRC 100
  • 2 Consult AWM for additional configurations
  • * Designates NFRC Gateway size

Typical Details

Select which format you would like to download:

PDF CAD

Coming Soon

This content has not been uploaded yet, but is coming soon. If you have any questions about this product please feel free to contact us.

Contact Us

We can test our windows to AAMA ratings that are amongst the highest in the country. Our total manufacturing control gives you total creative control.

Ken Thompson

Vice President - Sales