3200i Projected

  • Exterior View

  • Interior View

    Features & Information
  • Standard Features
    • Silicone structural glazing for maximum structural integrity
    • Equal sightline makes vents and fixed lites virtually indistinguishable from the exterior
    • Multi-point locks with advanced design Eurogroove hardware
    • Concealed heavy duty hinges allow for vents weighing up to 330 lbs.
    • Thermal strut thermal barrier at frame for enhanced performance and dual finish capability
    • Aesthetically pleasing flush vent design with beveled exterior glazing legs
    • AAMA 2603/2604/2605 painted or AAMA 611 anodized finishes
  • Optional Features
    • Concealed heavy duty hinges allow for vents weighing up to 330 lbs.
    • Extended length handles for reduced operating force in ADA applications
    • Offset glazed stacking frames to replicate hung windows
    • Between the glass muntin grids
    • Hurricane Windborne Debris Impact Resistance (Large Missile)
    • Limit devices for restricted opening (NYCDOH stamped where applicable)
    • Key operated locks
    • Insect screens (fiberglass, aluminum or stainless-steel mesh)
  • Performance Charts
  • Downloadable Details, Data Sheet + Specification
We have you covered

Architects must balance longevity, cost, risk and beauty while controlling the effects of temperature, water, wind, acoustics and storm-driven projectiles. Architects collaborate best with manufacturers driven by an equal passion for balance and control.

Performance Data1
Series Operation AMAA
Rating
Test Size
(inches)
Air (cfm/ft2)
@ 6.24 psf
Water
(psf)
Design Pressure
(psf)
Structural Overload
(psf)
OITC U-Factor
(BTU/HR/FT2/F)
3200i Project-In AW-PG70 60 x 144 <0.01 25 70 105 Consult AWM See Below
  • 1 Based on independent certified laboratory testing per AAMA/WDMA/CSA 101/I.S.2/A440. Field results will vary based on size, test methods, accessories & conditions.
Thermal Performance Chart1
Window Size (Inches) CENTER OF INSULATED GLASS U-FACTOR/SPACER TYPE (“Alum.” = Aluminum, “Warm” = Warm Edge) 2
0.33/Alum. 0.33/Warm 0.29/Alum. 0.29/Warm 0.24/Alum. 0.24/Warm 0.20/Alum. 0.20/Warm
59 x 24* projected 0.587 0.557 0.565 0.534 0.538 0.506 0.511 0.481
48 x 72** projected 0.498 0.477 0.472 0.450 0.441 0.418 0.403 0.382
47 x 59* fixed 0.467 0.451 0.441 0.425 0.411 0.394 0.377 0.361
  • 1Based on independent certified simulations in accordance with NFRC 100
  • 2Consult AWM for additional configurations
  • *Designates NFRC Gateway size
  • **Based on equal Fixed/PO
Thermal Performance Chart1
Window Size WHOLE WINDOW U-FACTOR USING ARGON FILLED SPUTTER COAT LOW-E #2 INSULATED GLASS WITH A WARM EDGE SPACER2 2
  • 1 Based on independent certified simulations in accordance with NFRC 100
  • 2 Consult AWM for additional configurations
  • * Designates NFRC Gateway size

Typical Details

Select which format you would like to download:

PDF CAD

Coming Soon

This content has not been uploaded yet, but is coming soon. If you have any questions about this product please feel free to contact us.

Contact Us

We can test our windows to AAMA ratings that are amongst the highest in the country. Our total manufacturing control gives you total creative control.

Ken Thompson

Vice President - Sales