6750i Horizontal Sliding

    Features & Information
  • Standard Features
    • Large multi-cavity custom thermal strut design provides maximum thermal performance for remarkably low u-values and dual finish capability
    • Outstanding structural performance and energy efficiency for occupant safety and comfort
    • Ideal for schools, high-rise residential, government buildings and hospitals
    • Single slide in XO, OXO or XOX configurations allow variable ventilation options
    • Smooth operating, high performance Delrin stainless steel ball bearing rollers
    • Structural silicone wet glazing delivers maximum seal strength and water resistance
    • Available with straight or beveled glazing legs for aesthetic design flexibility
  • Optional Features
    • Dual glazing with removable access panels (allows for vandal resistant polycarbonate glazing or 5/8" deep integral blinds, straight leg only)
    • True, exterior applied or between the lites of dual glazing muntin grids
    • 15 psf sill for increased water resistance
    • Half insect screens (fiberglass, aluminum or stainless-steel mesh)
    • Hurricane Windborne Debris Impact Resistance (Large Missile)
    • Limit devices for restricted opening (NYCDOH stamped where applicable)
  • Performance Charts
  • Downloadable Details, Data Sheet + Specification
We have you covered

Architects must balance longevity, cost, risk and beauty while controlling the effects of temperature, water, wind, acoustics and storm-driven projectiles. Architects collaborate best with manufacturers driven by an equal passion for balance and control.

Performance Data1
Series Operation AMAA
Rating
Test Size
(inches)
Air (cfm/ft2)
@ 6.24 psf
Water
(psf)
Design Pressure
(psf)
Structural Overload
(psf)
OITC U-Factor
(BTU/HR/FT2/F)
6750i Single Slide AW-PG80 99 x 79 0.20 12 80 120 Consult AWM See Below
  • 1 Based on independent certified laboratory testing per AMAA/WDMA/CSA/101/I.S.2/A440. Field results will vary based on size, test methods, accessories & conditions.
Thermal Performance Chart1
Window Size (Inches) CENTER OF INSULATED GLASS U-FACTOR/SPACER TYPE (“Alum.” = Aluminum, “Warm” = Warm Edge) 2
0.33/Alum. 0.33/Warm 0.29/Alum. 0.29/Warm 0.24/Alum. 0.24/Warm 0.20/Alum. 0.20/Warm
59 x 47* 0.485 0.465 0.460 0.439 0.431 0.409 0.393 0.375
72 x 48 0.469 0.451 0.443 0.424 0.412 0.392 0.373 0.357
  • 1Based on independent certified simulations in accordance with NFRC 100
  • 2Consult AWM for additional configurations
  • *Designates NFRC Gateway size
Thermal Performance Chart1
Window Size WHOLE WINDOW U-FACTOR USING ARGON FILLED SPUTTER COAT LOW-E #2 INSULATED GLASS WITH A WARM EDGE SPACER2 2
  • 1 Based on independent certified simulations in accordance with NFRC 100
  • 2 Consult AWM for additional configurations
  • * Designates NFRC Gateway size

Typical Details

Select which format you would like to download:

PDF CAD

Coming Soon

This content has not been uploaded yet, but is coming soon. If you have any questions about this product please feel free to contact us.

Contact Us

We can test our windows to AAMA ratings that are amongst the highest in the country. Our total manufacturing control gives you total creative control.

Ken Thompson

Vice President - Sales