8090i Fixed

  • Exterior View

  • Interior View

    Features & Information
  • Standard Features
    • Thermal strut thermal barrier for enhanced performance and dual finish capability
    • Wet glazed with structural silicone for maximum seal strength and water resistance
    • Mate with operable windows and doors as follows:
      • 8000i DH
    • Available with straight or beveled frames for design flexibility
  • Optional Features
    • Dual glazing with removable access panels (Allows for vandal resistant polycarbonate glazing or integral blinds)
    • True, exterior applied or between the lites of dual glazing muntin grids (Varies based on series – Consult AWM)
    • Hurricane Windborne Debris Impact Resistance (Large Missile)
  • Performance Charts
  • Downloadable Details, Data Sheet + Specification
We have you covered

Architects must balance longevity, cost, risk and beauty while controlling the effects of temperature, water, wind, acoustics and storm-driven projectiles. Architects collaborate best with manufacturers driven by an equal passion for balance and control.

Performance Data1
Series Operation AMAA
Rating
Test Size
(inches)
Air (cfm/ft2)
@ 6.24 psf
Water
(psf)
Design Pressure
(psf)
Structural Overload
(psf)
OITC U-Factor
(BTU/HR/FT2/F)
8090i Fixed AW-PG150 60 x 99 <0.01 25 150 225 Consult AWM See Below
  • 1 Based on independent certified laboratory testing per AAMA/WDMA/CSA 101/I.S.2/A440. Field results will vary based on size, test methods, accessories & conditions.
Thermal Performance Chart1
Window Size (Inches) CENTER OF INSULATED GLASS U-FACTOR/SPACER TYPE (“Alum.” = Aluminum, “Warm” = Warm Edge) 2
0.33/Alum. 0.33/Warm 0.29/Alum. 0.29/Warm 0.24/Alum. 0.24/Warm 0.20/Alum. 0.20/Warm
47 x 59* 0.455 0.431 0.424 0.399 0.388 0.361 0.343 0.320
  • 1Based on independent certified simulations in accordance with NFRC 100
  • 2Consult AWM for additional configurations
  • *Designates NFRC Gateway size
Thermal Performance Chart1
Window Size WHOLE WINDOW U-FACTOR USING ARGON FILLED SPUTTER COAT LOW-E #2 INSULATED GLASS WITH A WARM EDGE SPACER2 2
  • 1 Based on independent certified simulations in accordance with NFRC 100
  • 2 Consult AWM for additional configurations
  • * Designates NFRC Gateway size

Typical Details

Select which format you would like to download:

PDF CAD

Coming Soon

This content has not been uploaded yet, but is coming soon. If you have any questions about this product please feel free to contact us.

Contact Us

We can test our windows to AAMA ratings that are amongst the highest in the country. Our total manufacturing control gives you total creative control.

Ken Thompson